        Features of Infusion Pump 

        1. HD LCD Display, high capacity words, friendly user interface, dynamically display working status;

        2. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting, etc., which gain patents;

        3. Compatible with any brands of infusion sets after correct calibration;

        4. Preset solution volume to greatly reduce the workload of nurses;

        5. Work mode: ml/h and drop/min can switch freely;

        6. Three levels of occlusion: high, middle and low;

        7. Purge function;

        8. KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step);

        9. Power Source: AC100---240V, 50/60Hz; Internal Battery;

        10. Automatically record the settings of last infusion;

        11. OEM is available.

         

        Specification of Infusion Pump 

        Rate 

        1ml/h ~ 1,200ml/h 

        Flow Rate Accuracy 

        Within ±5% (after correct calibration) 

        Mechanical precision 

        Within ±2% 

        Purge Rate 

        100ml/h ~ 1,000ml/h (100 ml/h step) 

        Infusion Volume 

        1ml ~ 9999ml 

        Total Infusion Volume 

        0.1ml ~ 9999.9ml 

        KVO rate 

        1ml/h ~ 5 ml/h (1ml/h step) 

        Occlusion 

        High: 800mmHg ±200mmHg (106.7kPa±26.7kPa 
        Medium: 500mmHg ±100mmHg(66.7kPa±13.3kPa 
        Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa ) 

        Unique audible and visible alarm 

        Human voice alarm for End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc. 

        Power Source 

        AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup 

        Bubble detector 

        Ultrasonic wave detector; detection sensitivity ≥25μL 

        Fuse 

        F1AL/250V, 2 pc inside 

        Power Consumption 

        18VA 

        Operating Condition 

        Ambient temperature: +5℃ ~ +40℃; 
        Relative humidity: 20 ~ 90% 
        Atmospheric pressure: 86.0kpa ~ 106.0kpa 

        Transport & Storage Condition 

        Ambient temperature:-30℃ ~ +55℃ 
        Relative humidity: ≤95% 

        Equipment Classification 

        Class II, internal power supply, Type CF 

        IP Classification 

        IPX4 

        Dimension 

        140mm (L) ×157mm(W) ×220mm(H) 

        Weight 

        1.8kg (net weight)